Dynamic | Tianjin Honghe...
On September 16th to 17th, the Hydraulic Pollution Control Subcommittee of the National Hydraulic and Pneumatic Standardization Technical Committee held a national standard review meeting in Shanghai. More than 30 experts and representatives from industries/enterprises across the country attended the meeting.
Rainy season is coming, ...
After the instrument has been working for a certain period of time, especially in environments with high humidity, the air filtration combination may retain some moisture. You can check whether drainage is needed through the observation window on the back panel of the instrument. When drainage operation is required, the specific method is:
Sending oil samples to d...
Some customers use different brands of particle counters or send oil samples to different laboratories for testing in order to determine the true situation of oil contamination. However, they find that the test results are different. Why?
How many basic knowledge...
Working principle (photoresist method) When a liquid sample containing particles passes through the sensor's beam of light, a portion of the light is blocked by the particles, causing a change in light intensity. The amount of blocked light is proportional to the size of the particles. Therefore, by measuring the particles passing through the sensor
Teach you some tips for ...
The particle counter is a precision instrument, and if it is used for a long time, it may have some minor problems. However, the cost of returning the instrument to the factory for repair is high and the cycle is long. In this small class, we will teach you a few simple self checking and self-study tips about desktop computers. Let's learn them now!
荐 Let you learn about the ...
Friends who have followed the Honghe particle counter know that in addition to providing users with better pre-sales answers and after-sales maintenance services, we also constantly update the instrument performance
Honghe L20 meets your ex...
Precision Manufacturing - L20 Meets Your Expectations for Laboratory Instruments - Desktop Computer Main Features Desktop particle counter can be said to be the best choice for laboratory analytical instruments. Its structure is precise and complex, and its functions are also the most comprehensive, with high precision, high sensitivity, and high
Honghe Portable Wind res...
The portable particle counter is mainly designed for fluid particle detection that requires frequent changes in location. While inheriting the high standards and quality of Honghe products, we have also thoughtfully designed many operational details for the convenience of operators
荐 Details see quality, LPC...
We adhere to precision manufacturing. In recent years, the application of advanced detection instruments such as liquid particle counters in the civilian industry has reached unprecedented heights and breadth, while also placing higher demands on the quality and functionality of the instruments. According to applicable occasions and work conditions
Explanation of the Diffe...
The ACFTD size calibration method aims to determine the pollution level of solid particles. The definition of irregular shaped particle size is based on the longest chord diameter of the particle, with a standard particle size range of 1 μ m to 100 μ m. ACFTD calibration liquid particles
The impact of particle p...
The construction machinery industry has become an important pillar industry of China's national economic construction, and the reliability and stability of equipment operation are increasingly valued by people. Taking excavators as an example, according to relevant data statistics, about 50% of common faults occur in hydraulic systems
The basic difference bet...
The circulation of clean oil in the system is an important condition for ensuring the normal operation and lubrication of equipment, and solid particles are the most common and harmful pollutants in hydraulic and lubrication systems. By detecting the particle content in the oil, not only can the system be improved
What should I do if ther...
Gear oil is an important lubricating oil mainly composed of petroleum lubricating base oil or synthetic lubricating oil, mixed with extreme pressure anti-wear agents and oiliness agents. Industrial closed gear oil can improve the anti bonding performance of gears, prevent gear cracking, pitting, and bonding
Determination of Solid P...
Hydraulic oil plays a role in energy transfer, system lubrication, corrosion prevention, rust prevention, and cooling in hydraulic systems. Contaminants that remain and have not been removed from components and systems during processing, assembly, packaging, storage, and transportation, as well as from external sources during operation
What aspects should be n...
Whether the detection results of oil particle contamination are accurate and reliable depends not only on factors such as instruments and personnel, but also on whether the liquid sample taken can reflect the true pollution status of the system and represent the pollution level of the system, which is a very important part of it. In particulate pollution
Principles for selecting...
In order to obtain real and representative liquid samples, special consideration should be given to whether the system pipeline is in a turbulent flow state when selecting sampling points for LPC-M online sampling installation diagram, because in this state, the liquid sample exhibits intense agitation, causing the liquid to
Application of Particle ...
With the development of modern technology and the advancement of testing techniques, there is an increasing demand for online measurement and monitoring of the production process in terms of automation and large-scale production. Online detection technology is an important tool to ensure the accuracy of test results
荐 Operation Guide for Hong...
Test operation 1: Connect the power cord, press the power button to turn on the device, and the instrument completes self inspection; 2. Account login, enter the main interface; 3. Click on "Settings" and go to the "Test Settings" interface to perform the following steps: pre volume, sampling volume, sampling frequency, and sampling interval
Selection requirements a...
When conducting particle contamination testing, whether collecting sample liquid in the liquid tank or in the system pipeline for testing and analysis, the first thing to come into contact with is the sample container. The material, shape, cleaning, and cleaning method of the sampling container are the key to whether all subsequent work is meaningful. Collecting
Principles for selecting...
Oil monitoring is mainly used to evaluate the current status, degree of contamination, and lubrication and wear status of in use oil. Effective oil monitoring requires correct sampling procedures, therefore, obtaining representative oil samples is a prerequisite for accurate and reliable analysis results and is essential for oil monitoring