Clever application of automatic particle counter backwashing technology

Click: Time:2021-11-12 00:00:00

At present, the commonly used instrument for detecting oil contamination is the photoresist particle counter, which provides a fast and accurate particle size analysis method with many incomparable advantages. However, it also has its own limitations: larger particles in the oil will remain in the instrument, and even these pollutants will dry up in the sensor, increasing the difficulty of cleaning and shortening the service life of the instrument; At the same time, it will also affect the accuracy and service life of the instrument detection.


Clever application of backwashing technology


According to the principle of automatic particle counter, oil needs to enter the instrument measurement channel through a pump system or pressure system. When pollutants flow unidirectionally with the oil, due to the narrow sample slit of the measurement unit (usually with a diameter of less than 500 μ m and a maximum of no more than 1mm), the types and shapes of pollutants are complex and diverse. For example, high-density particles may settle in a certain part of the channel due to gravity; Hard particles with elongated shapes may become stuck; Fluffy pollutants may obstruct and attach new particles, accumulating more and more; Failure to clean the sensor channel in a timely manner after testing high viscosity samples, and the formation of an oil film after the residual liquid dries up... All of these situations may cause instrument blockage.


Experience has shown that when offline instruments become clogged during experiments, the pressure effect of the self-priming pump will weaken. During testing and sampling, changes in internal system pressure can cause backflow after injection, insufficient sampling pressure can cause bubble interference, and a decrease in injection volume, leading to inaccurate testing. It is usually possible to determine whether the instrument has been clogged by counting results that are too small or by reverse pumping phenomena; Online detection can be made by observing phenomena such as a small count or a decrease in outlet flow rate when external pressure stabilizes.


When the instrument is blocked, you can try changing the flow direction of the liquid for backwashing operation to flush out the residual or stuck blockage in a certain channel. After backwashing, most instrument blockages can be resolved, which is helpful for system maintenance, preventing system jamming, and extending service life. By using an automatic particle counter system for backwashing, the accuracy of oil sample contamination detection can be improved, the operating environment of the instrument can be improved, and the service life of the particle counter can be extended. Provide technical support to production plants, improve oil utilization rate, and reduce oil change costs. In addition, if there is still blockage after the recoil operation, please contact our after-sales engineer for other troubleshooting and maintenance work.


文章推荐

友情链接:

Tianjin Honghe Technology Co., Ltd

 

E-mail:sales01@tjhonghe.com

I would like to call the information hotline:

Tel  022-58956940

Add: 5F, Block C-D, Building 3, No.13 Ziyuan Road, Huayuan Industrial Park, Tianjin

Scan QR code Follow us:

图片展示

Copyright ©2022 Tianjin Honghe Technology Co., LTD.All Rights Reserved ICP record No. 19008642 -1

\©2022 Tianjin Honghe Technology Co., LTD. All Rights reserved

ICP备案号津ICP备19008642号-1

 

Service Center
全国热线电话
15102225673
Qrcode
扫码添加微信
添加微信好友,详细了解产品
使用企业微信
“扫一扫”加入群聊
复制成功
添加微信好友,详细了解产品
我知道了